por DINAKSA ESP | Oct 4, 2022
OverLoad Limiting Cell ADK
Load limiting Cell ADK has a capacity from 1,000 to 10,000 kg. and maximum cable diameter 30 mm. It is indicated for the limitation of loads in overhead cranes, tower cranes, elevator lifts, freight elevators, etc.
por DINAKSA ESP | Oct 3, 2022
Overload Limiting Cell LmDK
TECHNICAL CHARACTERISTICS
- Load cells designed for the measurement of loads in steel cables.
- Made of high-strength nickel-plated steel.
- Maximum robustness.
- Capacity: 3,5 tons – to need.
- 5 to 15 Vdc power supply
- Sensitivity approx. 1.5 mV / V
- Zero tolerance setting 2% F.E.
- Load limit without losing characteristics 200% F.E.
- Breaking load> 300% F.E
- Protection: IP66
- Supplied with 5 meters of cable.
por DINAKSA ESP | Oct 2, 2022
Load Cell Pin type Double cut DKBulon
Double cut Load Cell DKBulon, load Pin Manufacturing for any capacity and dimension.
The Load Pins allow to measure efforts in any point where an axle is placed, without making relevant mechanical changes.
We have considerable experience in making tailored sensors to suit all types of works and applications. Redundant load Pins, Stainless, waterproof, harsh.
por DINAKSA ESP | Sep 13, 2022
Load Cell Traction + Compression DKCTR
CAPACITY: 0.75, 1, 1.5, 2, 3, 5 Ton.
- Cell designed to work with traction forces, with sensor element under cut.
- Equipped with insulating bushings of high mechanical strength.
- Can be used with shackles, standard or specific moorings, for each capacity. Built in smelting.
por DINAKSA ESP | Sep 11, 2022
Load Cell Traction DKGH
Technical Data
Sensitivity: 2mV/V
Sensitivity tolerance adjustment: 0.1%
Zero tolerance adjustment: 1% F.E.
Excitation voltage: ≤ 12V
Non- linearity: <0.015% F.E.
non-repeatability: <0.011% F.E.
Error combinado <0.027% F.E.
hysteresis 0.009% F.E.
Fluency in 30 minutes <0.025% F.E.
Temp. effect in sensitivity <0.023% F.E.
Temp. effect at zero <0.016%/5ºC
Compensated temperature range -10ºC/+40ºC
input resistance 380Ω±10Ω
output resistance 350Ω±3Ω
isolation resistance (V.Test=100V) >5000 10⁵Ω
peak workload 150% F.E.
Load limit without losing features 200% F.E.
breaking load >300% F.E.
flexible cable 4×0.25mm
Protection IP 66
Anti-corrosion treatment of chemical nickel.